Over 50 Years of Differential Pressure Flow Metering Experience

Product Index









ORIPAC MODEL 4150-P
About the Oripac Model 4150-P Dimension Sheet Tech Support Sheet
Part No. Reference System Specification Sheet Installation Instructions
MODEL 4150-P DIMENSION SHEET

Specifications:

Weight: Varies with line size. (See chart)
Pressure: 150 psi max
Temperature: 140° F max (CPVC 190° max)
Head Loss: Similar to standard orifice plates - (refer to tech support sheet)
Fluids: Air and gases
Line Sizes: 1/4" to 24" standard - special sizes available
Installation: Standard flange - 125#/150# rating (orifice flanges not required)
Accuracy: ± 0.6% of full scale flow - (refer to tech support sheet)
Pipe Requirements: Refer to installation sheet. General requirements 5-10 dia. up stream and 2-3 dia. down stream.


DIMENSIONAL DRAWING click to enlarge


MODEL 4150-P
PVC CONSTRUCTION

DIMENSIONS IN INCHES
Thickness = 1.25"
On All Line Sizes

Line Size
(D)

Oripac
Outside
Diameter
(OD)

Pipe
Inside
Diameter
(PID)

Tap
Location
(CA)

Weight
(Pounds)

0.25"
0.50"
0.75"
1.00"
1.25"
1.50"
2.00"
2.50"
3.00"
4.00"
5.00"
6.00"
8.00"
10.0"
12.0"
14.0"
16.0"
18.0"
20.0"
24.0"

1.890"
1.890"
2.250"
2.625"
3.000"
3.375"
4.125"
4.875"
5.375"
6.875"
7.750"
8.750"
11.000"
13.374"
16.125"
17.750"
20.250"
21.625"
23.875"
28.250"

0.364"
0.622"
0.824"
1.049"
1.380"
1.610"
2.067"
2.469"
3.068"
4.026"
5.047"
6.065"
7.981"
10.020"
12.000"
14.000"
16.000"
18.000"
20.000"
24.000"

4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500

1
1
1
1
1
2
2
2
2
3
3
4
5
6
7
9
10
12
14
16

Dimensions based on 150#
Flange Rating and Standard Schedule Pipe

 

Tel: 631-587-1000 · Fax: 631-587-1011