Over 50 Years of Differential Pressure Flow Metering Experience

Product Index









ORIPAC MODEL 4150
About the Oripac Model 4150 Dimension Sheet Tech Support Sheet

Part No. Reference System Specification Sheet Installation Instructions
MODEL 4150 DIMENSION SHEET

Specifications:
Weight: Varies with line size. (See chart)
Pressure: 150 psi (300# flange rating available)
Temperature: 180° STD max (300° with Hi-Temp Resin)
Head Loss: Similar to standard orifice plates - (refer to tech support sheet)
Fluids: Air, gases and liquids
Line Sizes: 1" - 24" standard - special sizes available
Installation: Standard flange - 125#/150# rating (orifice flanges not required)
Accuracy: ± 0.6% of full scale flow - (refer to tech support sheet)
Pipe Requirements: Refer to installation sheet.


DIMENSIONAL DRAWING click to enlarge


MODEL 4150
Fiberglass with SS Plate
for Air/Gases/Liquids

DIMENSIONS IN INCHES
Thickness = 1.25" on all
Line Sizes

Line Size
(D)

Oripac
Outside
Diameter
(OD)

Pipe
Inside
Diameter
(PID)

Fitting
Angle
(CA)

Weight
(Pounds)

1"
1.25"
1.50"
2"
2.5"
3"
4"
5"
6"
8"
10"
12"
14"
15"
18"
20"
24"

2-5/8"
3"
3-3/8"
4-1/8"
4-7/8"
5-3/8"
6-7/8"
7-3/4"
8-3/4"
11"
13-3/8"
16-1/8"
17-3/4"
20-1/4"
21-5/8"
23-7/8"
28-1/4"

1.049"
1.380"
1.610"
2.067"
2.469"
3.068"
4.026"
5.047"
6.065"
7.931"
10.020"
12.000"
14.000"
16.000"
18.000"
20.000"
24.000"

180°
180°
180°
180°
180°
180°
180°
90°
90°
90°
60°
60°
60°
45°
45°
45°
45°

2
2
3
3
3
4
4
5
6
7
9
10
12
16
20
23
27

Dimensions Based on 150#
Flange Rating and
Standard Schedule Pipe
Thickness = 1.25" for All Line Sizes